Planning & selection

Cryostat

Specify chamber temperature, freezing performance, microtome capability, decontamination, extraction, and laboratory workflow.

Decisions to resolve

  1. 01 Chamber and specimen-head temperature range
  2. 02 Cooling and recovery performance
  3. 03 Sectioning specification and blade system
  4. 04 Defrost, disinfection, extraction, and waste handling

Evidence to request

  • Temperature stability and pull-down test
  • Sectioning demonstration
  • A dimensioned drawing with service clearances
  • A declared utility and connection schedule
  • A measurable factory and site acceptance procedure
  • Operation, cleaning, and preventive-maintenance documents

Model reference

View individual model parameters

Parameters are shown exactly as recorded for each model. Field names are not standardized across models, and this section does not provide side-by-side comparison.

RD-2265 Summary only

RD-2265 Cryostat

View parameters +

Dual-purpose knife holder (0-15° adjustable); sectioning 0μm–999.9μm (0.1μm increments); trimming 0μm–999.9μm; quick-freeze stage -65°C to RT (1°C graduation); 6 semiconductor stations; one-key position memory + auto-alignment; UVC sterilization; multi-user mode; timing & sleep mode; specimen retraction 0–999.9μm (0.1μm increments); CE, ISO certified; 1-year + lifetime support; OEM available

Detailed parameters have not yet been added to this model record. Confirm the current specification through the official product catalog.

Confirm current configuration, certification status, and final technical commitments before procurement.

Official catalog →
RD-2280 Summary only

RD-2280 Cryostat

View parameters +

SECOP dual-compressor with closed freezer cover plate; chamber 10°C to -60°C; Peltier shelf -60°C in 15 min; sectioning 0.5μm–100μm; intelligent temp control; 10-inch color LCD screen; UV sterilization; 24 freezing stations + 8 Peltier points; max specimen 55mm × 80mm; specimen retraction 0–100μm (5μm increments); CE, ISO 13485 certified; 1-year + lifetime support

Detailed parameters have not yet been added to this model record. Confirm the current specification through the official product catalog.

Confirm current configuration, certification status, and final technical commitments before procurement.

Official catalog →
RD-2260 Summary only

RD-2260 Pathology Cryostat Microtome

View parameters +

LED touch screen (Chinese/English interface); dual Danfoss compressors with dedicated cooling for chamber, shelf, blade, specimen; chamber -10°C to -40°C adjustable; Peltier -65°C (2 stations, 15 min); sectioning 1–100μm; trimming 5–500μm; retraction 0–90μm; quick-freeze shelf -45°C (26 stations); max specimen 55 × 60mm; UV sterilization; standby mode; CE certified

Detailed parameters have not yet been added to this model record. Confirm the current specification through the official product catalog.

Confirm current configuration, certification status, and final technical commitments before procurement.

Official catalog →
RD-2290 Summary only

RD-2290 Cryostat

View parameters +

Secop dual-compressor with 5-point separate cooling; Peltier-assisted rapid freezing to -65°C in 15 min; 10.1-inch color LCD touchscreen with multi-language support; sectioning 0.5–100 μm; trimming 0–600 μm; retraction 0–60 μm; UVC disinfection; nano-coated stainless steel chamber; seamless interior; one-touch memory function; programmable sleep mode; CE certified

Detailed parameters have not yet been added to this model record. Confirm the current specification through the official product catalog.

Confirm current configuration, certification status, and final technical commitments before procurement.

Official catalog →

Commercial next step

Review current configurations with Roundfin.

Use the planning decisions above when requesting drawings, certification documents, configuration options, and a quotation.

Official Catalog